  "revision": 7,
  "status": "digital checks pass; physical operation unverified",
  "checks": {
    "meshChecks": 936,
    "phaseChecks": 26,
    "dialChecks": 104,
    "markerChecks": 182,
    "attachmentChecks": 182,
    "calibrationModes": 2,
    "daysSampledPerMode": 13,
    "referenceDays": 366
  },
  "accuracy": {
    "sun": {
      "meanAbsoluteErrorDeg": 0.3108514465802661,
      "maxAbsoluteErrorDeg": 0.5443608950745845
    },
    "moon": {
      "meanAbsoluteErrorDeg": 1.7354387083882925,
      "maxAbsoluteErrorDeg": 4.458512705594102
    },
    "mercury": {
      "meanAbsoluteErrorDeg": 4.280750348454906,
      "maxAbsoluteErrorDeg": 14.222029722588475
    },
    "venus": {
      "meanAbsoluteErrorDeg": 1.1834009809184236,
      "maxAbsoluteErrorDeg": 3.3009325624528287
    },
    "mars": {
      "meanAbsoluteErrorDeg": 10.593259773185551,
      "maxAbsoluteErrorDeg": 19.309294509902738
    },
    "jupiter": {
      "meanAbsoluteErrorDeg": 0.3982125202044088,
      "maxAbsoluteErrorDeg": 1.317665136413268
    },
    "saturn": {
      "meanAbsoluteErrorDeg": 0.18488198131232292,
      "maxAbsoluteErrorDeg": 0.3192099190752575
    }
  },
  "limitations": [
    "Analytical kinematics; no force/contact dynamics.",
    "Sampled assembly checks do not prove whole-assembly clearance.",
    "New frame and dial joints have separate exact-solid checks.",
    "No physical printing, assembly, stiffness, torque or durability test."
  ]
}